5910-00-134-9614 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-00-134-9616 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-00-134-9615

Federal Supply Class:
5910

National Item Identification Number:
001349615

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
184-8607-00013499ROCKWELL COLLINS, INC.
CL23BL1R5TNE81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC3965-1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONNONPOLARIZED
ANODE TYPEETCHED FOIL
BODY DIAMETER0.219 INCHES MAXIMUM
BODY LENGTH0.688 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITIVE ELECTRODE MATERIALTANTALUM
CAPACITANCE VALUE PER SECTION1.500 MICROFARADS SINGLE SECTION
CASE MATERIALMETAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP4.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP2.000 MICROAMPERES
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS2255.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION75.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
POWER FACTOR AT REFERENCE TEMP IN PERCENT15.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-3965/18 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-15.00 TO 50.00 PERCENT SINGLE SECTION