ELECTRICAL RESISTANCE | 30.900 OHMS |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
BODY HEIGHT | 0.015 INCHES MINIMUM AND 0.033 INCHES MAXIMUM |
BODY LENGTH | 0.098 INCHES MINIMUM AND 0.112 INCHES MAXIMUM |
BODY WIDTH | 0.095 INCHES MINIMUM AND 0.105 INCHES MAXIMUM |
INCLOSURE METHOD | UNINCLOSED |
POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
RELIABILITY INDICATOR | ESTABLISHED |
SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-55342/9 GOVERNMENT SPECIFICATION |
STYLE DESIGNATOR | TERMINATION PAD EACH END |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 150.0 |
TERMINAL LENGTH | 0.010 INCHES MINIMUM AND 0.020 INCHES MAXIMUM |
TERMINAL TYPE | TERMINAL TYPE PER BODY STYLE |
TEST DATA DOCUMENT | 81349-MIL-PRF-55342 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |