2810-01-353-2958 RING,PISTON Index 5905-01-353-2960 RESISTOR,THERMAL

National Stock Number:
5905-01-353-2959

Federal Supply Class:
5905

National Item Identification Number:
013532959

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
38TD350056PIEZOTHERMX CORPORATION
7548470-4299971LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE SYSTEMS


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER125.0 CELSIUS
BODY HEIGHT0.007 INCHES MINIMUM AND 0.017 INCHES MAXIMUM
BODY LENGTH0.040 INCHES MAXIMUM
BODY WIDTH0.040 INCHES MAXIMUM
INCLOSURE TYPEUNINCLOSED
MAXIMUM OPERATING TEMP125.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING125.00 MILLIWATTS
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-11.0 TO 11.0 1ST RESISTANCE-TEMPERATURE POINT-8.5 TO 8.5 2ND RESISTANCE-TEMPERATURE POINT-7.0 TO 7.0 3RD RESISTANCE-TEMPERATURE POINT-5.0 TO 5.0 4TH RESISTANCE-TEMPERATURE POINT-7.0 TO 7.0 5TH RESISTANCE-TEMPERATURE POINT-11.9 TO 11.9 6TH RESISTANCE-TEMPERATURE POINT-12.5 TO 12.5 7TH RESISTANCE-TEMPERATURE POINT
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.000 TO 5.000
ZERO POWER RESISTANCE8.000 KILOHMS
STYLE DESIGNATORCHIP
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT-20.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT0.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT25.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT50.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT100.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT125.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TERMINAL TYPE AND QUANTITY1 SURFACE CONTACT