5905-01-342-8235 RESISTOR,FIXED,WIRE WOUND Index 5905-01-342-8237 RESISTOR,FIXED,WIRE WOUND,NONIND

National Stock Number:
5905-01-342-8236

Federal Supply Class:
5905

National Item Identification Number:
013428236

Description:
RESISTOR,FIXED,WIRE WOUND,NONIND

Detail:
INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.


Manufacturer Information:
MIL-PRF-39007/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39007/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR81N2R00BS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE2.000 OHMS
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
BODY DIAMETER0.065 INCHES MINIMUM AND 0.105 INCHES MAXIMUM
BODY LENGTH0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM
CUBIC MEASURE0.001 CUBIC INCHES
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTS1.000 FREE AIR
REACTANCE CHARACTERISTICNONINDUCTIVE
RESISTANCE TOLERANCE IN PERCENT-0.100 TO 0.100
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RELIABILITY INDICATORESTABLISHED
SPECIFICATION/STANDARD DATA81349-MIL-R-39007/9 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-50.0 TO 50.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 275.0
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).