5950-01-260-8639 TRANSFORMER,POWER Index 5905-01-260-8641 RESISTOR,THERMAL

National Stock Number:
5905-01-260-8640

Federal Supply Class:
5905

National Item Identification Number:
012608640

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
1745-105347ULTRONIX INC
985824-00116224TITAN CORP THE
985824-00163702L-3 SERVICES, INC. DBA COMMAND & CONTROL SYSTEMS SOFTWARE & EXPEDITIONARY OPERATION
S764609359MINCO PRODUCTS INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY LENGTH0.350 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.100 INCHES NOMINAL
CUBIC MEASURE0.004 CUBIC INCHES
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP125.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING0.25 WATTS
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-1.0 TO 1.0 ALL RESISTANCE-TEMPERATURE POINTS
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.1136 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.2339 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.3603 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.4925 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP893.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-1.0 TO 1.0
ZERO POWER RESISTANCE1.000 KILOHMS
ZERO POWER RESISTANCE AT SPECIFIED TEMP689.3 OHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP722.7 OHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP776.1 OHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP833.2 OHMS 4TH RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORROD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-15.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-30.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-45.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER75.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL LENGTH1.200 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TEST DATA DOCUMENT16224-985824 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Click here to Register for Free 30-day Trial