EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 5400.0 MINIMUM AND 10800.0 MAXIMUM |
ELECTRICAL RESISTANCE PER SECTION | 500.0 OHMS SINGLE SECTION |
ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
ACTUATOR TYPE | SINGLE SHAFT |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
BODY HEIGHT | 0.360 INCHES MINIMUM AND 0.390 INCHES MAXIMUM |
BODY LENGTH | 0.420 INCHES MAXIMUM |
BODY WIDTH | 0.140 INCHES MINIMUM AND 0.240 INCHES MAXIMUM |
BODY STYLE | RECTANGULAR |
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
CUBIC MEASURE | 0.039 CUBIC INCHES |
FEATURES PROVIDED | HUMIDITY PROOF |
FRAGILITY FACTOR | MODERATELY RUGGED |
FUNCTION CHARACTERISTIC PER SECTION | SINGLE SECTION LINEAR |
FUNCTION CONFORMITY PER SECTION | SINGLE SECTION INDEPENDENT LINEARITY |
FUNCTION CONFORMITY TOLERANCE PER SECTION | -1.000 TO 1.000 SINGLE SECTION |
MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
MOUNTING METHOD | TERMINAL |
POWER DISSIPATION RATING PER SECTION IN WATTS | 0.75 FREE AIR SINGLE SECTION |
RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
RELIABILITY INDICATOR | NOT ESTABLISHED |
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 5400.0 MINIMUM AND 10800.0 MAXIMUM |
SECTION QUANTITY | 1 |
SHAFT DIAMETER | 0.050 INCHES MINIMUM AND 0.100 INCHES MAXIMUM |
SHAFT LENGTH | 0.080 INCHES MAXIMUM |
SHAFT STYLE | ROUND, SLOTTED |
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0 TO 50.0 SINGLE SECTION |
TERMINAL LENGTH | 0.172 INCHES MINIMUM |
TERMINAL LOCATION | REAR END |
TERMINAL TYPE AND QUANTITY | 3 PIN |
TEST DATA DOCUMENT | 73030-ED741501 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |