6130-01-199-0173 POWER SUPPLY ASSEMBLY Index 7025-01-199-0175 CONVERTER,FREQUENCY,STATIC

National Stock Number:
5905-01-199-0174

Federal Supply Class:
5905

National Item Identification Number:
011990174

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
811972-80137695RAYTHEON COMPANY


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
INCLOSURE TYPEENCASED
MAXIMUM OPERATING TEMP150.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING500.00 MILLIWATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS4.0
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESTHERMAL MOUNTED IN CASE
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.0 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT73.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT32.7 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT3.6 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT1.5 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT675.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT338.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE10.000 KILOHMS
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT-15.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT0.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT50.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT75.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT100.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT125.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS8.0