5905-01-166-2708 RESISTOR,FIXED,FILM Index 5935-01-166-2710 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5905-01-166-2709

Federal Supply Class:
5905

National Item Identification Number:
011662709

Description:
RESISTOR,FIXED,WIRE WOUND,INDUCT

Detail:
INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.


Manufacturer Information:
MIL-R-39007/1281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILR39007-1281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR82S2470BR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RWR82S2470DR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE247.000 OHMS
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER275.0
BODY DIAMETER0.078 INCHES NOMINAL
BODY LENGTH0.312 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTS1.500 FREE AIR
RESISTANCE TOLERANCE IN PERCENT-0.100 TO 0.100
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
RELIABILITY INDICATORESTABLISHED
SPECIFICATION/STANDARD DATA81349-MIL-R-39007/12 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-20.0 TO 20.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 275.0
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-39007 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).