5950-01-164-2489 REACTOR Index 5910-01-164-2491 CAPACITOR,VARIABLE,CERAMIC DIELECTRIC

National Stock Number:
5905-01-164-2490

Federal Supply Class:
5905

National Item Identification Number:
011642490

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
651-4540-00113499ROCKWELL COLLINS, INC.
651-4540-00195105ROCKWELL COLLINS, INC.


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY HEIGHT0.060 INCHES NOMINAL
BODY LENGTH0.150 INCHES NOMINAL
BODY WIDTH0.150 INCHES NOMINAL
HEATER RESISTANCE TOLERANCE IN PERCENT-1.0 TO 1.0
HEATER RESISTANCE39.200 OHMS
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.6
REFERENCE TEMP IN DEG CELSIUS25.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-11.0 TO 11.0 4TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.0 TO 12.0 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.0 TO 12.0 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.0 TO 13.0 6TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-17.0 TO 17.0 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.0 TO 18.0 2ND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-19.0 TO 19.0 8TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-21.0 TO 21.0 9TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-23.0 TO 23.0 10TH RESISTANCE-TEMPERATURE POINT
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.2 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP100.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP14.7 OHMS 9TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP17.9 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP174.7 OHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP29.8 OHMS 8TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP3.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-4.40
ZERO POWER RESISTANCE AT SPECIFIED TEMP359.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP6.6 OHMS 10TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP67.5 OHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE1.000 KILOHMS
STYLE DESIGNATORSQUARE OR RECTANGULAR WAFER
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-30.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER130.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER160.0 CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER20.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER200.0 CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER70.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL LENGTH2.000 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY4 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS5.0