5905-01-161-3201 RESISTOR,FIXED,FILM Index 5905-01-161-3203 RESISTOR,FIXED,FILM

National Stock Number:
5905-01-161-3202

Federal Supply Class:
5905

National Item Identification Number:
011613202

Description:
RESISTOR,FIXED,FILM

Detail:
A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of either a thin layer of conductive material, containing either binders or insulating materials, deposited on an insulated form; or an alloy of metal and ceramic materials, usually fused to an insulated form. Opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the resistor. See also ATTENUATOR, FIXED and RESISTOR, FIXED, COMPOSITION. Excludes carbon composition type resistors.


Manufacturer Information:
005 ITT 05101 2180N0002ALCATEL-LUCENT NORWAY AS
1-4-5P18E80031MEPCO/ELECTRA INC
13-02124-0015476COMPAQ FEDERAL LLC
24773-231P09553MARCONI ELECTRONICS INC MARCONI INSTRUMENTS DIV
301-0180-0080009TEKTRONIX, INC.
4130180-0034257EIP MICROWAVE INC
4702-0180-00351190VIAVI SOLUTIONSLLC
6417-180561423KIDDE TECHNOLOGIES, INC
7903642-9090536LOCKHEED MARTIN CORP
CF-1/4-18OHM-5P11502INTERNATIONAL RESISTIVE COMPANY, INC. DIV WIRE AND FILM TECHNOLOGIES (WAFT)
MIL-PRF-39017/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-22684/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39017/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILR3901781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RL07S180G81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C180GP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C180GR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C180JM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C180JP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C180JR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C18R0GM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C18R0GP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C18R0GR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C18R0GS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07C18R0JP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07CS180G81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RLR07S180GM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
S9546-18070210HONEYWELL INTERNATIONAL INC.


Techincal Specification:
ELECTRICAL RESISTANCE18.000 OHMS
AMBIENT TEMP AT FULL RATED POWER70.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER150.0
BODY DIAMETER0.090 INCHES NOMINAL
BODY LENGTH0.250 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
NUCLEAR HARDNESS CRITICAL FEATUREHARDENED
POWER DISSIPATION RATING IN WATTS0.250 FREE AIR
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RESISTANCE TOLERANCE IN PERCENT-2.000 TO 2.000
RELIABILITY INDICATORESTABLISHED
SPECIAL FEATURESNUCLEAR HARDNESS CRITICAL ITEMS
SPECIFICATION/STANDARD DATA81349-MIL-R-39017/1 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-100.0 TO 100.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 150.0
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-39017 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
UNPACKAGED UNIT WEIGHT0.500 GRAMS