9330-01-077-3979 TUBING,NONMETALLIC Index 4140-01-077-3981 FAN,CENTRIFUGAL

National Stock Number:
5905-01-077-3980

Federal Supply Class:
5905

National Item Identification Number:
010773980

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
730152-2680249BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
TM1/8 103K01295TEXAS INSTRUMENTS INCORPORATED
TM1/8 103K12969MICRO USPD INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER100.0 CELSIUS
BODY LENGTH0.390 INCHES MINIMUM AND 0.420 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP125.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING125.00 MILLIWATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.5
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.3 TO 10.3 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.1 TO 12.1 6TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.8 TO 12.8 4TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.3 TO 14.3 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0 2ND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.6 TO 14.6 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.1 TO 16.1 1ST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.2 TO 16.2 8TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.5 TO 18.5 9TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.0 TO 20.0 10TH RESISTANCE-TEMPERATURE POINT
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP20.0 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP22.3 KILOHMS 10TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.7 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP5.4 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP6.6 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP12.0 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP14.1 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP16.7 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP8.2 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE10.000 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.70
STYLE DESIGNATORROD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER75.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-25.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-75.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-65.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS35.0


Click here to Register for Free 30-day Trial