AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
BODY LENGTH | 0.410 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.140 INCHES NOMINAL |
INCLOSURE TYPE | ENCAPSULATED |
MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
MAXIMUM POWER DISSIPATION RATING | 500.00 MILLIWATTS |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 5TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 1ST RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 6TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0 TO 7.0 3RD RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 2ND RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0 TO 9.0 4TH RESISTANCE-TEMPERATURE POINT |
RELIABILITY INDICATOR | NOT ESTABLISHED |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 37.4 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 50.1 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 81.6 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 102.6 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 130.6 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 96.6 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
ZERO POWER RESISTANCE | 680.000 OHMS |
STYLE DESIGNATOR | ROD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
TERMINAL LENGTH | 1.250 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
TEST DATA DOCUMENT | 81349-MIL-T-23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |