5962-01-041-3863 MICROCIRCUIT,LINEAR Index 5905-01-041-3865 RESISTOR,FIXED,FILM

National Stock Number:
5905-01-041-3864

Federal Supply Class:
5905

National Item Identification Number:
010413864

Description:
RESISTOR,FIXED,WIRE WOUND

Detail:
INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.


Manufacturer Information:
MIL-PRF-39005/381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39005/381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RBR5414040BR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RBR54L14040BR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE1.404 KILOHMS
AMBIENT TEMP AT FULL RATED POWER125.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER145.0
BODY DIAMETER0.250 INCHES NOMINAL
BODY LENGTH0.750 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTS0.250 FREE AIR
RESISTANCE TOLERANCE IN PERCENT-0.100 TO 0.100
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
RELIABILITY INDICATORESTABLISHED
SPECIFICATION/STANDARD DATA81349-MIL-R-39005/3 GOVERNMENT SPECIFICATION
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-10.0 TO 10.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-65.0 TO 145.0
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MIL-R-39005 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial