5905-01-041-2812 RESISTOR,VARIABLE,WIRE WOUND,NON Index 5905-01-041-2814 RESISTOR,VARIABLE,WIRE WOUND,PRE

National Stock Number:
5905-01-041-2813

Federal Supply Class:
5905

National Item Identification Number:
010412813

Description:
RESISTOR,VARIABLE,WIRE WOUND,NON

Detail:
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.


Manufacturer Information:
176S501J17826TECHNO COMPONENTS CORP DBA TECHNO COMPONENTS
1867853-619315HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS FORMER BENDIX NAVIGATION AND CONTROL SYSTEMS
1867853-655972HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS
215-72HS5000EBU2VAMISTOR/WESTON DIV OF VAMISTOR CORP OF TENNESSEE INC
215-72HS50094271LOCKHEED MARTIN CORP
255-72H500OHMS0EBU2VAMISTOR/WESTON DIV OF VAMISTOR CORP OF TENNESSEE INC
255-72H500OHMS94271LOCKHEED MARTIN CORP
39015-3-009XM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
444-0495-08894756THE BOEING COMPANY
916-0706-0015A0307ALENIA SISTEMI DIFESA SPA
916-0706-0015A0810LEONARDO - SOCIETA' PER AZIONI
A3-83-135918HORIZON AEROSPACE LLC DBA MAGNETICS DIVISION
M39015-03-009XP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39015-3-009XP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39015/03-006XP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39015/3-006XR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39015/3-00XM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39015/3-00XP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39015/3-00XR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39015/381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39015/381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RTR24C2X50181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RTR24DX501M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RTR24DX501P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RTR24DX501R81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION7200.0 MINIMUM AND 15120.0 MAXIMUM
ELECTRICAL RESISTANCE PER SECTION500.0 OHMS SINGLE SECTION
ACTUATOR TRAVEL CONTROL FEATURECLUTCH
ACTUATOR TYPESINGLE SHAFT
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER85.0 SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER150.0 SINGLE SECTION
BODY HEIGHT0.420 INCHES MAXIMUM
BODY LENGTH0.375 INCHES NOMINAL
BODY WIDTH0.170 INCHES NOMINAL
BODY STYLERECTANGULAR
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL0.100 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.200 INCHES NOMINAL
FRAGILITY FACTORMODERATELY DELICATE
MOUNTING METHODTERMINAL
POWER DISSIPATION RATING PER SECTION IN WATTS0.75 FREE AIR SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
RESISTANCE TOLERANCE PER SECTION IN PERCENT-5.0 TO 5.0 SINGLE SECTION
RELIABILITY INDICATORESTABLISHED
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG9000.0 NOMINAL
SECTION QUANTITY1
SHAFT DIAMETER0.075 INCHES NOMINAL
SHAFT LENGTH0.080 INCHES MAXIMUM
SHAFT STYLEROUND, SLOTTED
SPECIFICATION/STANDARD DATA81349-MIL-R-39015/3 GOVERNMENT SPECIFICATION
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS-50.0 TO 50.0 SINGLE SECTION
TERMINAL LENGTH0.300 INCHES MINIMUM
TERMINAL LOCATIONLOWER ADJACENT SIDE SINGLE ROW
TERMINAL TYPE AND QUANTITY3 PIN
TEST DATA DOCUMENT81349-MIL-R-39015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial