National Stock Number: 5905-01-023-5829
Federal Supply Class: 5905
National Item Identification Number: 010235829
Description: RESISTOR,VARIABLE,NONWIRE WOUND,
Detail: A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
|
Manufacturer Information:
111244-01 | 14345 | ROLM CORP MIL SPEC COMPUTERS | 14-000522-022 | 50460 | CAELUS MEMORIES INC DIS DRIVE DIV | 14-000522-022 | 63123 | FARRIS M & ASSOCIATES | 3101121 | 55257 | RAMTEK CORP | 3339H-1-401 | 80294 | BOURNS INSTRUMENTS INC | 3339H-1-501 | 32997 | BOURNS INC | 339H-1-501 | 32997 | BOURNS INC | 3718282-6 | 49671 | LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES | 4600-05-0108 | 23338 | WAVETEK U S INC DIV OF WAVETEK CORP |
|
Techincal Specification:
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 1440.0 NOMINAL | ELECTRICAL RESISTANCE PER SECTION | 500.0 OHMS SINGLE SECTION | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION | BODY DIAMETER | 0.300 INCHES NOMINAL | BODY LENGTH | 0.250 INCHES NOMINAL | BODY STYLE | CYLINDRICAL | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL | OVERALL DIAMETER | 0.300 INCHES NOMINAL | OVERALL LENGTH | 0.500 INCHES NOMINAL | MOUNTING METHOD | TERMINAL | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION | RELIABILITY INDICATOR | NOT ESTABLISHED | SECTION QUANTITY | 1 | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION | TERMINAL LENGTH | 0.250 INCHES NOMINAL | TERMINAL LOCATION | REAR END | TERMINAL TYPE AND QUANTITY | 3 PIN |
|
|