4720-01-019-3856 HOSE ASSEMBLY,NONMETALLIC Index 5910-01-019-3858 CAPACITOR,VARIABLE,AIR DIELECTRI

National Stock Number:
5905-01-019-3857

Federal Supply Class:
5905

National Item Identification Number:
010193857

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
ERT42499251MISSION SYSTEMS DAVENPORT INC.
GB41R102606BAXTER HEALTHCARE CORPORATION DBA BAXTER BIOTECH DIV TRANSFUSION THERAPIES


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY LENGTH0.438 INCHES MAXIMUM
BODY OUTSIDE DIAMETER0.100 INCHES MAXIMUM
INCLOSURE TYPEHERMETICALLY SEALED
MAXIMUM OPERATING TEMP300.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS1.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.6 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP132.0 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP273.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-3.90
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.0 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP425.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP47.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP550.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP900.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-20.0 TO 20.0
ZERO POWER RESISTANCE10.000 KILOHMS
STYLE DESIGNATORBEAD TYPE EVACUATED OR GAS FILLED ENVELOPE
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-10.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-30.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-50.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER120.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER80.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.012 INCHES NOMINAL
TERMINAL LENGTH2.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS25.0


Click here to Register for Free 30-day Trial