5905-00-994-7135 RESISTOR,FIXED,WIRE WOUND,INDUCT Index 5905-00-994-7137 RESISTOR,FIXED,WIRE WOUND,INDUCT

National Stock Number:
5905-00-994-7136

Federal Supply Class:
5905

National Item Identification Number:
009947136

Description:
RESISTOR,FIXED,WIRE WOUND,INDUCT

Detail:
INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.


Manufacturer Information:
114-004354817AUTEK SYSTEMS CORP
114-04354817AUTEK SYSTEMS CORP
16-000307-01150460CAELUS MEMORIES INC DIS DRIVE DIV
710-3946-00013499ROCKWELL COLLINS, INC.
BW1-2-4-3P0RM5PC75042TRW INC TRW ELECTRONIC COMPONENTS IRC FIXED RESISTORS PHILADELPHIA DIV
BWH4-3OHM5PCT58022R F PRODUCTS, INC
BWH4R3J75042TRW INC TRW ELECTRONIC COMPONENTS IRC FIXED RESISTORS PHILADELPHIA DIV
CW2C1U4R0F91637VISHAY DALE ELECTRONICS, LLC
MIL-PRF-26/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILR2681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RW69V4R381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
RESISTANCE TOLERANCE IN PERCENT-5.000 TO 5.000
RELIABILITY INDICATORNOT ESTABLISHED
STYLE DESIGNATORAXIAL TERMINAL EACH END
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-400.0 TO 400.0
ELECTRICAL RESISTANCE4.300 OHMS
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER350.0
BODY DIAMETER0.188 INCHES NOMINAL
BODY LENGTH0.500 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
POWER DISSIPATION RATING IN WATTS3.000 FREE AIR
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-55.0 TO 350.0
TERMINAL TYPEWIRE LEAD
TEST DATA DOCUMENT81349-MILR26/4 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).