5950-00-789-5182 COIL,ELECTRICAL Index 5915-00-789-5187 SUPPRESSOR,PARASITIC

National Stock Number:
5905-00-789-5186

Federal Supply Class:
5905

National Item Identification Number:
007895186

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
2D159752531HITACHI MAGNETICS CORP DIV OF HITACHI METALS INTERNATIONAL LTD
930C616-289954BAE SYSTEMS CONTROLS INC.
RL1007-624-73-S1075263KEYSTONE CARBON CO INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY OUTSIDE DIAMETER0.170 INCHES MAXIMUM
BODY WIDTH0.170 INCHES MAXIMUM
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS8.0
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS
ZERO POWER RESISTANCE AT SPECIFIED TEMP410.4 OHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP52.02 OHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP53.52 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP624.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP7.842 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE1.000 KILOHMS
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.813 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP21.39 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP30.4 OHMS 8TH RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORDISK
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-21.5 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-40.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER37.8 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.013 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS28.0