ELECTRICAL RESISTANCE PER SECTION | 5.0 KILOHMS SINGLE SECTION |
ACTUATOR TYPE | SINGLE SHAFT |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
BODY HEIGHT | 0.300 INCHES MINIMUM AND 0.330 INCHES MAXIMUM |
BODY LENGTH | 1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
BODY WIDTH | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.300 INCHES MINIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.890 INCHES MINIMUM AND 0.910 INCHES MAXIMUM |
FEATURES PROVIDED | NONMETALLIC SHAFT |
FRAGILITY FACTOR | MODERATELY DELICATE |
LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 0.890 INCHES MINIMUM AND 0.910 INCHES MAXIMUM |
OVERALL HEIGHT | 0.769 INCHES MINIMUM AND 0.861 INCHES MAXIMUM |
OVERALL LENGTH | 1.300 INCHES MINIMUM AND 1.340 INCHES MAXIMUM |
OVERALL WIDTH | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
MAXIMUM STARTING TORQUE | 8.00 INCH-OUNCES |
MOUNTING HOLE DIAMETER | 0.093 INCHES NOMINAL |
MOUNTING METHOD | TERMINAL |
POWER DISSIPATION RATING PER SECTION IN WATTS | 0.8 FREE AIR SINGLE SECTION |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0 TO 10.0 SINGLE SECTION |
SECTION QUANTITY | 1 |
SHAFT DIAMETER | 0.100 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
SHAFT LENGTH | 0.060 INCHES MINIMUM AND 0.080 INCHES MAXIMUM |
SHAFT STYLE | ROUND, SLOTTED |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-22097/2 GOVERNMENT SPECIFICATION |
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -250.0 TO 250.0 SINGLE SECTION |
TERMINAL LENGTH | 0.469 INCHES MINIMUM AND 0.531 INCHES MAXIMUM |
TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |
TERMINAL TYPE AND QUANTITY | 3 PIN |
TEST DATA DOCUMENT | 81349-MIL-R-22097 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |