5905-00-774-7853 RESISTOR,THERMAL Index 5315-00-774-7867 KEY,WOODRUFF

National Stock Number:
5905-00-774-7854

Federal Supply Class:
5905

National Item Identification Number:
007747854

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
0837-001628480HEWLETT-PACKARD COMPANY
TM1-4-3301K01295TEXAS INSTRUMENTS INCORPORATED
TM1-4-332K01295TEXAS INSTRUMENTS INCORPORATED
TM1-43300-10PCT96214RAYTHEON COMPANY


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER100.0 CELSIUS
BODY LENGTH0.585 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.200 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING250.00 MILLIWATTS
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.1 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP6.1 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP7.3 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP8.5 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP9.7 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE3.300 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS0.70
ZERO POWER RESISTANCE AT SPECIFIED TEMP10.5 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORROD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-75.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER125.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER75.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS60.0