5340-00-709-2018 MOUNT,RESILIENT Index 5950-00-709-2022 REACTOR

National Stock Number:
5905-00-709-2019

Federal Supply Class:
5905

National Item Identification Number:
007092019

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
0839-00271LQK8KEYSIGHT TECHNOLOGIES, INC.
0839-002728480HEWLETT-PACKARD COMPANY
0839-00277ZXR5KEYSIGHT TECHNOLOGIES INC
120420-00181413BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
335C764H0179500WESTINGHOUSE ELECTRIC CORP
335C764H0197942NORTHROP GRUMMAN SYSTEMS CORPORATION
L0903-25K140R75263KEYSTONE CARBON CO INC


Techincal Specification:
BODY OUTSIDE DIAMETER0.110 INCHES MAXIMUM
INCLOSURE TYPEUNINCLOSED
MAXIMUM OPERATING TEMP150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.9
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.8 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP14.3 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP184.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP25.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE46.900 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-5.08
ZERO POWER RESISTANCE AT SPECIFIED TEMP460.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP720.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORBEAD
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-21.5 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER104.4 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER37.8 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.010 INCHES NOMINAL
TERMINAL LENGTH2.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS10.0


Click here to Register for Free 30-day Trial