5910-00-671-2401 CAPACITOR,FIXED,PAPER DIELECTRIC Index 4310-00-671-2454 RING SET,PISTON

National Stock Number:
5905-00-671-2409

Federal Supply Class:
5905

National Item Identification Number:
006712409

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
ES72820418DRS SUSTAINMENT SYSTEMS, INC. USE CAGE CODE 98255 FOR CATALOGING
ES72898255DRS SUSTAINMENT SYSTEMS INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER125.0 CELSIUS
BODY HEIGHT0.375 INCHES NOMINAL
BODY LENGTH0.500 INCHES NOMINAL
BODY WIDTH0.188 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM CURRENT RATING25.00 AMPERES
MAXIMUM OPERATING TEMP200.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING2.50 WATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS5.5
REFERENCE TEMP IN DEG CELSIUS25.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-5.0 TO 5.0 ALL RESISTANCE-TEMPERATURE POINTS
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP246.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP946.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
ZERO POWER RESISTANCE492.000 OHMS
STYLE DESIGNATORWAFER
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-21.5 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER37.8 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS50.0