5910-00-547-8599 CAPACITOR,FIXED,ELECTROLYTIC Index 5950-00-547-8605 REACTOR

National Stock Number:
5905-00-547-8604

Federal Supply Class:
5905

National Item Identification Number:
005478604

Description:
RESISTOR,VARIABLE,WIRE WOUND,NON

Detail:
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.


Manufacturer Information:
044-109412175UNITRON INC
138-062-310395542NORTHROP GRUMMAN SYSTEMS CORPORATION
138-062-3103C1834KONTRON AG
205-208-100000HM11502INTERNATIONAL RESISTIVE COMPANY, INC. DIV WIRE AND FILM TECHNOLOGIES (WAFT)
205-208-100000HM84048VERNITRON CORP VRN INTERNATIONAL DIV
205-208-10384048VERNITRON CORP VRN INTERNATIONAL DIV
3255W-10K80294BOURNS INSTRUMENTS INC
325CW1-10380294BOURNS INSTRUMENTS INC
M39015/2-007WP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39015/2-007WR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39015/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILR39015-281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RCR07G822JS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RTR22DW103P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL RESISTANCE PER SECTION10.000 KILOHMS SINGLE SECTION
ACTUATOR TYPESINGLE SHAFT
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER85.0 SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER150.0 SINGLE SECTION
BODY HEIGHT0.500 INCHES NOMINAL
BODY LENGTH0.515 INCHES NOMINAL
BODY STYLERECTANGULAR W/MOUNTING HOLES
BODY WIDTH0.205 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL0.100 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.200 INCHES NOMINAL
LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS0.520 INCHES NOMINAL
OVERALL HEIGHT0.500 INCHES NOMINAL
OVERALL LENGTH0.702 INCHES MINIMUM
OVERALL WIDTH0.205 INCHES NOMINAL
MOUNTING FACILITY QUANTITY2
MOUNTING HOLE DIAMETER0.073 INCHES NOMINAL
MOUNTING METHODUNTHREADED HOLE AND TERMINAL
POWER DISSIPATION RATING PER SECTION IN WATTS0.75 FREE AIR SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.100
RELIABILITY INDICATORESTABLISHED
RESISTANCE TOLERANCE PER SECTION IN PERCENT-5.0 TO 5.0 SINGLE SECTION
SECTION QUANTITY1
SHAFT LENGTH0.078 INCHES NOMINAL
SHAFT DIAMETER0.045 INCHES MAXIMUM
SHAFT STYLEROUND, SLOTTED
SPECIFICATION/STANDARD DATA81349-MIL-R-39015/2 GOVERNMENT SPECIFICATION
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS-50.0 TO 50.0 SINGLE SECTION
TERMINAL LENGTH0.172 INCHES MINIMUM
TERMINAL LOCATIONREAR END
TERMINAL TYPE AND QUANTITY3 PIN
TEST DATA DOCUMENT81349-MIL-R-39015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).