AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
INCLOSURE TYPE | HERMETICALLY SEALED |
MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
MAXIMUM POWER DISSIPATION RATING | 75.00 MILLIWATTS |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 1.0 |
PROBE DIAMETER | 0.100 INCHES MAXIMUM |
PROBE LENGTH | 0.500 INCHES NOMINAL |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
RELIABILITY INDICATOR | NOT ESTABLISHED |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 45.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.5 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 820.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 14.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -20.0 TO 20.0 |
ZERO POWER RESISTANCE | 100.000 OHMS |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -3.20 |
STYLE DESIGNATOR | PROBE |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.012 INCHES NOMINAL |
TERMINAL LENGTH | 2.000 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
THERMAL TIME CONSTANT IN SECONDS | 22.0 |