5905-00-001-2838 RESISTOR,VARIABLE,NONWIRE WOUND, Index 5905-00-001-2842 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5905-00-001-2840

Federal Supply Class:
5905

National Item Identification Number:
000012840

Description:
RESISTOR,FIXED,WIRE WOUND

Detail:
INC 37404 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.


Manufacturer Information:
MIL-R-39005/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
RBR52L16150BR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
POWER DISSIPATION RATING IN WATTS0.500 FREE AIR
TERMINAL LENGTH1.500 INCHES MINIMUM
SPECIFICATION/STANDARD DATA81349-MIL-R-39005/1 GOVERNMENT SPECIFICATION
ELECTRICAL RESISTANCE1.615 KILOHMS
STYLE DESIGNATORAXIAL TERMINAL EACH END
BODY DIAMETER0.375 INCHES NOMINAL
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS-65.0 TO 145.0
AMBIENT TEMP AT FULL RATED POWER125.0 DEG CELSIUS
BODY LENGTH1.000 INCHES NOMINAL
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS-10.0 TO 10.0
RESISTANCE TOLERANCE IN PERCENT-0.100 TO 0.100
RELIABILITY INDICATORESTABLISHED
TEST DATA DOCUMENT81349-MIL-R-39005 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER145.0
TERMINAL TYPEWIRE LEAD
INCLOSURE TYPEENCAPSULATED


Click here to Register for Free 30-day Trial