ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ENCLOSURE FEATURE | SINGLE ITEM W/CARRYING CASE |
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL 1ST OPERATING POWER RQMT |
CUBIC MEASURE | 2671.24 CUBIC INCHES |
FREQUENCY RATING | 400.0 HERTZ NOMINAL 1ST OPERATING POWER RQMT |
FUNCTIONAL DESCRIPTION | TESTS ALIGNMENT OF THE ENCODER AND THE SYNCHRO TRANSMITTERS WHEN ASSEMBLING THE GEAR AND PLATE ASSEMBLY, P/N 1616234-3; PART OF THE ALTITUDE ENCODING ALTITUDE TRANSDUCER COMPUTER, P/N 31101 |
HEIGHT | 10.340 INCHES NOMINAL |
LENGTH | 20.120 INCHES NOMINAL |
MAJOR COMPONENTS | AUTOTRANSFORMER; VOLTMETER; 2 AUTOSYN INDICATORS; A RECTIFIER CIRCUIT; NETWORK ASSY; INDICATING LAMPS; ASSOCIATED CABLES AND CONTROLS |
PHASE | SINGLE 1ST OPERATING POWER RQMT |
REFERENCE DATA AND LITERATURE | T.O. 33D7-3-91-1 |
SPECIAL FEATURES | PREVIOUSLY CALLED GEAR TRAIN ASSEMBLY TEST STAND |
WIDTH | 12.840 INCHES NOMINAL |
SUPPLEMENTARY FEATURES | VOLTMETER M1 AND TRANSISTORIZED SERVOED INDICATORS B1 AND B2 REQUIRE CALIBRATION EVERY 90 DAYS OR 600 OPERATING HOURS; CABLE ASSY 1 USED TO CONNECT THE TEST STAND TO THE POWER SOURCE; CABLE ASSY 2 USED TO CONNECT THE UNIT UNDER TEST TO THE TEST STAND |
TEST TYPE FOR WHICH DESIGNED | ALIGNMENT TEST GEAR AND PLATE ASSY |