3120-01-006-5053 BUSHING,SLEEVE Index 4820-01-006-5055 VALVE,GATE

National Stock Number:
4810-01-006-5054

Federal Supply Class:
4810

National Item Identification Number:
010065054

Description:
VALVE,SOLENOID

Detail:
A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.


Manufacturer Information:
963-A3/4D2809990PARKER-HANNIFIN CORPORATION
963A3-4D2886768TELEDYNE INDUSTRIES INC TELEDYNE FLUID SYSTEMS REPUBLIC BUSINESS UNIT


Techincal Specification:
APERTURE DIAMETER0.032 INCHES NOMINAL
CONNECTION TYPETHREADED INTERNAL BOSS 1ST END
CONNECTION STYLEGASKET SEAL(BOSS) 1ST END
CURRENT RATING IN AMPS0.300
FLOW CONTROL DEVICE NORMAL OPERATION POSITIONCLOSED
MATERIALALUMINUM ALLOY 2024 BODY
MAXIMUM OPERATING PRESSURE5000.0 POUNDS PER SQUARE INCH SINGLE RESPONSE
MAXIMUM OPERATING TEMP20.0 FAHRENHEIT SINGLE RESPONSE
MEDIA FOR WHICH DESIGNEDHYDRAULIC FLUID, MINERAL BASE SINGLE RESPONSE
MOUNTING POSITIONHORIZONTAL OR VERTICAL
NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED0.250 INCHES 1ST END
NOMINAL THREAD SIZE0.438 INCHES 1ST END
PHASESINGLE
STYLE DESIGNATORSTRAIGHT THRU
SURFACE TREATMENTANODIZE
THREAD CLASS3B 1ST END
THREAD DIRECTIONRIGHT-HAND 1ST END
THREAD SERIES DESIGNATORUNJF 1ST END
VALVE OPERATION METHODSOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC