BURST TEST PRESSURE | 25000.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
HYDROSTATIC TEST PRESSURE | 12500.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
INSIDE DIAMETER | 0.500 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | 1ST LAYER SPIRALLY LAID STEEL WIRE AND 2ND LAYER SPIRALLY LAID STEEL WIRE AND 3RD LAYER SPIRALLY LAID STEEL WIRE AND 4TH LAYER SPIRALLY LAID STEEL WIRE AND OUTER LAYER MOLDED RUBBER, CHLOROPRENE |
OUTER COVERING ENVIRONMENTAL PROTECTION | OIL RESISTANT AND OZONE RESISTANT |
OUTSIDE DIAMETER | 1.062 INCHES MINIMUM AND 1.125 INCHES MAXIMUM |
MATERIAL | RUBBER BUTADIENE-ACRYLONITRILE CLASS NBR OR RUBBER CHLOROPRENE CLASS CR TUBE |
MAXIMUM OPERATING PRESSURE | 6250.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
MINIMUM INSIDE BENDING RADIUS | 8.000 INCHES |
NONDEFINITIVE SPEC/STD DATA | 100R10 TYPE |
SPECIFICATION/STANDARD DATA | 81349-MIL-H-52471C GOVERNMENT SPECIFICATION |
TEMP RATING | -40.0 FAHRENHEIT AND 212.0 FAHRENHEIT SINGLE RESPONSE |