END CONNECTION DESIGN | STRAIGHT 1ST END |
END FITTING COMPONENT AND MATERIAL | COMPLETE FITTING COPPER ALLOY ALL ENDS |
BURST TEST PRESSURE | 1000.0 POUNDS PER SQUARE INCH |
CONNECTION STYLE | INVERTED FLARE 1ST END |
CONNECTION TYPE | THREADED EXTERNAL PIPE 1ST END |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
HYDROSTATIC TEST PRESSURE | 500.0 POUNDS PER SQUARE INCH |
INSIDE DIAMETER | 0.375 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | OUTER LAYER MOLDED RUBBER |
OUTER COVERING ENVIRONMENTAL PROTECTION | FUEL RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT AND OZONE RESISTANT |
OUTSIDE DIAMETER | 0.625 INCHES NOMINAL |
MAXIMUM OPERATING PRESSURE | 250.0 POUNDS PER SQUARE INCH |
MEASURING METHOD AND LENGTH | 36.000 INCHES NOMINAL OVERALL |
MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
NOMINAL THREAD SIZE | 0.375 INCHES 1ST END |
SEAT ANGLE | 30.0 DEGREES 1ST END |
SPECIAL FEATURES | INNER CONVEYING TUBE MATERIAL-RUBBER, SYNTHETIC; FURNISHED W/ONE STEEL ADAPTER UNION,3/8-18 NPTF INTERNAL THD TO 3/8-18 NPSM INTERNAL THD |
VACUUM IN TORR | 254.0 |
SPECIFICATION/STANDARD DATA | MIL MIL-H-13444,TYPE 1 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION |
TEMP RATING | -65.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |
THREAD CLASS | 2A 1ST END |
THREAD DIRECTION | RIGHT-HAND 1ST END |
THREAD SERIES DESIGNATOR | UNF 1ST END |