4320-01-586-6727 PLATE,CAM,PUMP Index 4320-01-587-1971 HOUSING,HYDRAULIC MOTOR,NON AIRC

National Stock Number:
4320-01-587-0865

Federal Supply Class:
4320

National Item Identification Number:
015870865

Description:
PUMP,RECIPROCATING

Detail:
A positive displacement device which utilizes the reciprocating motion of one or more pistons, plungers, or diaphragms within a complete or partial enclosure as a means of transferring a liquid from one place to another. It is designed to be driven manually or by a prime mover which is not an integral part of the pump.


Manufacturer Information:
0149-276944940CUMMINS POWER GENERATION INC.
0149-276971425AIRTEX PRODUCTS DIV OF UIS INC
04-2000244940CUMMINS POWER GENERATION INC.
149-276944940CUMMINS POWER GENERATION INC.
E1102571425AIRTEX PRODUCTS DIV OF UIS INC


Techincal Specification:
DISCHARGE PRESSURE9.7 POUNDS PER SQUARE INCH GAGE
MEDIA FOR WHICH DESIGNEDFUEL
OPERATION METHODPOWERED
PART NAME ASSIGNED BY CONTROLLING AGENCYPUMP, FUEL ELECTRIC
SPECIAL FEATURESOVERALL LENGTH 169.2 MM
SPECIAL TEST FEATURESREVERSE POLARITY: NO DAMAGE WITH EXTERNAL REVERSE POLARITY DIODE; CURRENT DRAW: (PUMP CONNECTED TO 24VDC SOURCE INDEPENDENT OF UNIT CONTROLS) 1.2 AMP TRUE RMS MAXIMUM; TRANSIENT VOLTAGE (INPUT TO FUEL PUMP): REPEATED TRANSIENT SPIKES OF 200 VOLTS AND 3 AMP FOR 60 MICROSEC AT 30HZ; OPERATING TEMPERATURE: -50 DEGRESS FAHRENHEIT TO +135 DEGREES FAHRENHEIT (PUMP AND FUEL); MINIMUM BIO LIFE: 2000 HOURS; PUMP SHALL HAVE AN INTERNAL CHECK VALVE TO PREVENT LOSS OF PRIME WHEN IT IS NOT OPERATING; PUMP SHALL BE CAPABLE OF CONTINUOUS PUMPING WITH A 75% VAPOR / LIQUID FUEL RATIO; PUMP SHALL NOT CREATE ANY DETRIMENTAL DEBRIS FROM ITS OPERATION; PUMP PRINTED CIRCUIT BOARD SHALL BE POTTED; PUMP SHALL HAVE AN INTERNAL ANTI-SIPHON VALVE; SPECIFICATIONS - FUEL: FUEL PUMP MUST BE CAPABLE OF OPERATING PER ASTM 10 OR 20 DIESEL A-A-52557 FUELS AND COMMERCIAL ADDITIVES, JP5 PER MIL-DTL-5624 AND JP8 PER MIL-DTL-8313
SPECIFICATION/STANDARD DATA05047-ASME Y14.100 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD
STORAGE TEMP RANGE-50.0 TO 150.0 FAHRENHEIT
SUPPLEMENTARY FEATURESMAXIMUM PRESSURE - ZERO FLOW: 66.9 KPA (9.7 PSI); MINIMUM FUEL FLOW: 75.7 1/HR (15.0 GPH) WITH MINIMUM 13.79 KPA (2.0 PSI) DELIVERY PRESSURE AT 23 VOLTS; SELF PRIMING DRY: MUST PRIME WITH 914.4MM (36") OF FUEL LIFT IN 15 SECONDS AT 16 VOLTS; DRY PUMP INTAKE VACUUM: 76.2 (3") HG MINIMUM AT 16 VOLTS; OPERATING VOLTAGE: 16 TO 28 VOLTS DC NEGATIVE GROUND


Click here to Register for Free 30-day Trial