CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | DOUBLE |
CENTRIFUGAL PUMP DESIGN | AXIAL FLOW |
CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
COOLING METHOD | AIR TO AIR COOLED |
CURRENT RATING IN AMPS | 2.1 |
CURRENT TYPE | AC |
DISCHARGE CONNECTION QUANTITY | 1 |
DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1.250-11-1/2 NPT |
DISCHARGE CONNECTION TYPE | THREADED INTERNAL |
DISCHARGE PRESSURE | 1.3 POUNDS PER SQUARE INCH GAGE |
ENVIRONMENTAL PROTECTION | DRIPPROOF |
FREQUENCY IN HERTZ | 60.0 |
INCLOSURE TYPE | FULLY INCLOSED |
MAXIMUM DISCHARGE FLOW RATE | 66.6 GALLONS PER MINUTE AND 15.0 GALLONS PER MINUTE |
MEDIA FOR WHICH DESIGNED | WATER, FRESH |
MOUNTING TYPE | BASE |
PHASE | SINGLE |
PRIME MOVER COOLING MEDIUM | AIR |
PRIME MOVER POWER RATING | 0.33 HORSEPOWER |
PRIME MOVER QUANTITY | 1 |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PUMP QUANTITY | 1 |
PUMPING ELEMENT OPERATING POSITION | VERTICAL |
STAGE QUANTITY | 1 |
SPECIAL FEATURES | SUMP DEPTH 26-17/32 IN.,MIN SUMP DIA 21 IN; PLASTIC FLOAT W/STAINLESS STEEL ROD; BRONZE IMPELLER;THREADED STAINLESS STEEL SHAFT; BRASS PIPE; CAST BRONZE BASE,VOLUTE; 8FT 3-CONDUCTOR CORD,PLUG |
TOTAL HEAD | 5.000 FEET AND 20.000 FEET |
VOLTAGE IN VOLTS | 115.0 |