CENTRIFUGAL PUMP DESIGN | AXIAL FLOW |
CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
COOLING METHOD | AIR TO AIR COOLED |
CURRENT RATING IN AMPS | 0.3 |
CURRENT TYPE | AC |
DISCHARGE CONNECTION QUANTITY | 1 |
DISCHARGE CONNECTION TYPE | OVAL FLANGE |
FREQUENCY IN HERTZ | 60.0 |
INCLOSURE TYPE | PARTIALLY INCLOSED |
INTAKE CONNECTION QUANTITY | 1 |
INTAKE CONNECTION TYPE | OVAL FLANGE |
OPERATING SPEED AT RATED CAPACITY | 1500.0 REVOLUTIONS PER MINUTE |
MAXIMUM DISCHARGE FLOW RATE | 21.7 GALLONS PER MINUTE AND 4.8 GALLONS PER MINUTE |
MEDIA FOR WHICH DESIGNED | WATER, FRESH |
PHASE | SINGLE |
PRIME MOVER COOLING MEDIUM | AIR |
PRIME MOVER POWER RATING | 0.05 HORSEPOWER |
PRIME MOVER QUANTITY | 1 |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PUMP BASIC MATERIAL | IRON |
PUMP QUANTITY | 1 |
SPECIAL FEATURES | LINE MTD; FLANGES MUST BE ORDERED SEPARATELY |
STAGE QUANTITY | 1 |
TOTAL HEAD | 1.000 FEET AND 7.000 FEET |
UNPACKAGED UNIT HEIGHT | 6.312 INCHES NOMINAL |
UNPACKAGED UNIT LENGTH | 9.688 INCHES NOMINAL |
UNPACKAGED UNIT WIDTH | 4.8120 INCHES NOMINAL |
VOLTAGE IN VOLTS | 115.0 |