PUMP QUANTITY | 1 |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PUMP BODY MATERIAL | ANY ACCEPTABLE |
BODY SURFACE TREATMENT | ANY ACCEPTABLE |
VACUUM RATING | 0.1 MILLITORR |
SYSTEM DESIGN | NONCORROSIVE |
SPECIFIC GAS FOR WHICH DESIGNED | AIR |
PUMPING ELEMENT TYPE | SLIDING VANE |
STAGE QUANTITY | 2 |
VAPOR CONDENSATION PREVENTATIVE DEVICE | GAS BALLAST VALVING |
COOLING MEDIUM | OIL |
INTAKE CONNECTION QUANTITY | 1 |
INTAKE CONNECTION TYPE | UNTHREADED INTERNAL |
INTAKE CONNECTION INSIDE DIAMETER | 1.625 INCHES NOMINAL |
DISCHARGE CONNECTION QUANTITY | 1 |
DISCHARGE CONNECTION TYPE | UNTHREADED INTERNAL |
DISCHARGE CONNECTION INSIDE DIAMETER | 1.625 INCHES NOMINAL |
CURRENT TYPE | AC |
VOLTAGE IN VOLTS | 115.0 |
FREQUENCY IN HERTZ | 60.0 |
PHASE | SINGLE |
BRAKE HORSEPOWER REQUIRED | 1.000 |
OPERATING SPEED AT RATED CAPACITY IN RPM | 1725.0 |
AIR DISPLACEMENT RATE | 13.3 CUBIC FEET PER MINUTE IN FREE AIR |
MOUNTING TYPE | BASE |
DRIVE CONNECTION TYPE | MULTISTRAND V-BELT |
SAFETY DEVICE TYPE | OVERLOAD RELAY |
CONTROL DEVICE TYPE | CONSTANT SPEED |
FURNISHED ITEMS | BELT GUARD AND |
| V-BELT |
OVERALL HEIGHT | 18.750 INCHES NOMINAL |
OVERALL LENGTH | 25.625 INCHES NOMINAL |
OVERALL WIDTH | 13.125 INCHES NOMINAL |
FUNCTIONAL DESCRIPTION | THIS VACUUM PUMP IS A LARGE CAPACITY HIGH-VACUUM DUO-SEAL PUMP OF TWO STAGE CONSTRUCTION WITH VENTED EXHAUST;THIS PUMP IS DESIGNED FOR THE REMOVAL OF PERMANENT GASES SUCH AS AIR AND HYDROGEN AND CONDENSABLE VAPORS SUCH AS WATER AND SOLVENT; IT IS USED FOR EVACUATING COMPONENTS OF HEATING,VENTILATING COMPONENTS OF THE HEATING,VENTILATING AND AIR CONDITIONING SYS,PROPELLANT TRANSFER SYS AND VARIOUS GAGES DURING MAINTENANCE OPERATIONS; APPLICABLE TO TITAL II MISSILE PROGRAM |
ENTRY DATE | 85-08-15 |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 64484 |
DESIGN CONTROL REFERENCE | 1397B |