ANGULAR DEVIATION OF FIRST HOLE FROM TOP CENTER IN DEG | 193.0 |
ANGULAR DEVIATION OF SECOND HOLE FROM FIRST HOLE IN DEG | 167.0 |
BOTTOM MOUNTING HOLE DIAMETER | 0.316 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
DISTANCE BETWEEN INSIDE SURFACES OF HINGE BRACKET | 7.115 INCHES MINIMUM AND 7.139 INCHES MAXIMUM |
DISTANCE BETWEEN OUTSIDE SURFACES OF HINGE BRACKET | 7.935 INCHES MINIMUM AND 7.959 INCHES MAXIMUM |
DISTANCE BETWEEN SHAFT CENTER AND BOTTOM MOUNTING HOLE CENTER | 3.062 INCHES NOMINAL |
DISTANCE BETWEEN SHAFT CENTER AND TOP MOUNTING HOLE CENTER | 3.060 INCHES NOMINAL |
GROUNDING METHOD | INTERNAL |
KEYWAY LENGTH | 0.625 INCHES NOMINAL |
KEYWAY WIDTH | 0.125 INCHES NOMINAL |
MOUNTING HOLE THREAD DIRECTION | RIGHT-HAND |
MOUNTING HOLE THREAD DIAMETER | 0.312 INCHES NOMINAL |
MOUNTING HOLE THREAD QUANTITY PER INCH | 18 |
MOUNTING HOLE THREAD SERIES DESIGNATOR | UNC |
MOUNTING STYLE | BRACKET MTD W/THREE MTG HOLES, TOP HOLE THREADED |
SECOND STEP DIAMETER | 0.668 INCHES MINIMUM AND 0.669 INCHES MAXIMUM |
SHAFT DRIVE END STYLE | STRAIGHT SHAFT END, THREADED, W/KEYWAY |
SHAFT ROTATION DIRECTION | CLOCKWISE |
SUBMERSIBILITY | NONSUBMERSIBLE |
THREAD DIRECTION | RIGHT-HAND |
THREAD LENGTH | 0.490 INCHES NOMINAL |
THREAD SERIES | UNS |
UNTHREADED PORTION LENGTH | 0.810 INCHES NOMINAL |
VOLTAGE IN VOLTS | 12.0 |