Search Criteria

NSN/NIIN No.:
Part No. :
(13-16 digit NSN/9 digit NIIN)
5985-01-271-30445985-01-271-3042
NSNDescriptionAssign Date
5985-01-271-3043LINE,RADIO FREQUENCY TRANSMISSIO01/22/1988
NSNDescriptionDetailOpen Solicitations
5985-01-271-3043LINE,RADIO FREQUENCY TRANSMISSIO0
CompanyAward DateQuantityPriceContractDelivery Date
Free Trial01/02/1991Free TrialFree TrialDLA90091DC004
For additional information Register for Free Trial
Part NumberCompanyCAGE
BP15125BURKE PRODUCTS INC27361
22977-14756CIRCLE PRIME MANUFACTURING INC0HHN4
22977-14756BURKE PRODUCTS INC27361
22977-14756MYAT, INC.28035
22977-14756FISICA APPLIED TECHNOLOGIES, INC.50643
22977-14756ALEK INDUSTRIES INC65534
For additional information Register for Free Trial
NameValue
OVERALL LENGTH14.756 INCHES
END ITEM IDENTIFICATIONE2B/C-DCN RADOME
CONDUCTOR QUANTITY2
INSULATION SPACER SHAPEO-SHAPED
ACCOMMODATED CONDUCTOR TYPEPARALLEL
For additional information Register for Free Trial
CodeDefinition
ACQUISITION METHOD CODE.
'All Departments1SUITABLE FOR COMPETITIVE ACQUISITION.
ACQUISITION METHOD SUFFIX CODE.
'All DepartmentsCTHIS PART REQUIRES ENGINEERING SOURCE APPROVAL BY THE DESIGN CONTROL ACTIVITY IN ORDER TO MAINTAIN THE QUALITY OF THE PART. AN ALTERNATE SOURCE MUST QUALIFY IN ACCORDANCE WITH THE DESIGN CONTROL ACTIVITY’S PROCEDURES, AS APPROVED BY THE COGNIZANT GOVERNMENT ENGINEERING ACTIVITY. VALID AMCS: 1, 2, 3, 4 AND 5.
MAJOR ORGANIZATIONAL ENTITY.
NavyDNNavy
Defense Logistics Agency.DSDefense Logistics Agency.
PRICE
All DepartmentsPrice338.20
PRECIOUS METALS INDICATOR CODES.
All DepartmentsAItem does not contain Precious Metal.
CRITICALITY CODE.
All DepartmentsXThe item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
AUTOMATIC DATA PROCESSING EQUIPMENT.
All Departments
ELECTROSTATIC DISCHARGE CODE.
All Departments
HAZARDOUS MATERIALS INDICATOR CODE.
All DepartmentsPIndicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
DEMILITARIZATION CODE.
All DepartmentsBUSML Items – Mutilation to the point of scrap required worldwide. (Note 7). (See DODI 2030.08 for scrap definition).
For additional information Register for Free Trial
LINE,RADIO FREQUENC IF THE APPLICABLE (OEM OR MILITARY) DRAWING, SPECIFICATION, STANDARD, OR QUALITY ASSURANCE PROVISION (QAP) SPECIFIES AN ACCEPTABLE QUALITY LEVEL (AQL), THE SAMPLING ACCEPTANCE NUMBER SHALL BE REDUCED TO ZERO (0). FOR EXAMPLE, IF THE ACCEPT REJECT CRITERIA IS ACCEPT ON (3) DEFECTS AND REJECT ON (4) DEFECTS, THE NEW ACCEPT REJECT CRITERIA IS ACCEPT ON (0) DEFECTS AND REJECT THE ENTIRE LOT ON (1) DEFECT. EVEN THOUGH THE ACCEPTANCE LEVEL IS ELIMINATED, THE SAMPLE SIZE REMAINS THE SAME. ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE OFFERS IS NOT AVAILABLE AT THE PROCUREMENT AGENCY. THE OFFEROR MUST PROVIDE A COMPLETE DATA PACKAGE INCLUDING DATA FOR THE APPROVED AND ALTERNATE PART FOR EVALUATION. DLAD PROVISION 52.211-9009 IS APPLICABLE TO THIS SOLICITATION, THEREFORE SURPLUS MATERIAL WILL NOT BE CONSIDERED. IF PRESENT IN THE SOLICITATION, PROVISION 52.211-9003 AND CLAUSE 52.211-9000 ARE NOT APPLICABLE.
Cage# 0HHN4 and PartNumber# 22977-14756
Cage# 65534 and PartNumber# 22977-14756
Cage# 50643 and PartNumber# 22977-14756
Cage# 28035 and PartNumber# 22977-14756