ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
CRITICALITY CODE JUSTIFICATION | FEAT |
ENVIRONMENTAL PROTECTION | FUNGUS PROOF |
FEATURES PROVIDED | OVER VOLTAGE PROTECTOR |
INPUT CONNECTION QUANTITY | 3 SINGLE OPERATING POWER RQMT |
INPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE SINGLE OPERATING POWER RQMT |
INPUT VOLTAGE RATING | 118.0 AC VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
INPUT VOLTAGE RATING | 205.0 AC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
INPUT FREQUENCY RATING | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
OPERATING AMBIENT TEMP RANGE | -54.0 TO 75.0 CELSIUS |
OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
OUTPUT CONNECTION TYPE | CONNECTOR, RECEPTACLE SINGLE POWER OUTPUT |
OUTPUT CURRENT RATING | -5.0 DC AMPERES NOMINAL 6TH POWER OUTPUT |
OUTPUT CURRENT RATING | -7.0 DC AMPERES NOMINAL 7TH POWER OUTPUT |
OUTPUT CURRENT RATING | 45.0 DC AMPERES NOMINAL 5TH POWER OUTPUT |
OUTPUT CURRENT RATING | 5.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
OUTPUT CURRENT RATING | 7.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
OUTPUT CURRENT RATING | 7.5 DC AMPERES NOMINAL 2ND POWER OUTPUT |
OUTPUT CURRENT RATING | 8.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
OUTPUT VOLTAGE RATING | -16.0 DC VOLTS NOMINAL 6TH POWER OUTPUT |
OUTPUT VOLTAGE RATING | -40.0 DC VOLTS NOMINAL 7TH POWER OUTPUT |
OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 5TH POWER OUTPUT |
OUTPUT VOLTAGE RATING | 9.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
OUTPUT VOLTAGE RATING | 16.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
OUTPUT VOLTAGE RATING | 28.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
OUTPUT VOLTAGE RATING | 40.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
OVERALL HEIGHT | 4.250 INCHES NOMINAL |
OVERALL LENGTH | 17.500 INCHES NOMINAL |
OVERALL WIDTH | 8.360 INCHES NOMINAL |
MAXIMUM OPERATING ALTITUDE RATING | 55000.0 FEET |
POWER SUPPLY EFFICIENCY LINE | 80.0 |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY SOURCE CONTROL DRAWING |
SPECIAL FEATURES | ELECTROSTATIC SENSITIVE DEVICE; UNDERVOLTAGE PROTECTOR; SURGE PROTECTOR |
VENTILATION DESIGN TYPE | AIR COOLED |