5999-00-503-3467 DELAY LINE Index 5998-01-292-6602 CIRCUIT CARD ASSEMBLY

National Stock Number:
5999-00-519-5376

Federal Supply Class:
5999

National Item Identification Number:
005195376

Description:
DELAY LINE

Detail:
AN ITEM WHICH PROVIDES A PREDETERMINED DELAY TO AN ELECTRICAL PULSE, WHILE MAINTAINING SUBSTANTIALLY THE SAME WAVEFORM. THE DELAY IS OBTAINED BY MEANS OF A REAL OR ARTIFICIAL TRANSMISSION LINE OR EQUIVALENT DEVICE. THE EQUIVALENT DEVICE MAY BE ACOUSTIC, DISTRIBUTIVE, LUMPED CONSTANT, MAGNETIC SOLID STATE, OR SURFACE ACOUSTICAL WAVE TYPE. SEE ALSO ATTENUATOR, (AS MODIFIED); TRANSFORMER, (AS MODIFIED); AND OSCILLATOR, PULSE DELAY.


Manufacturer Information:
173-10203927SAFETRAN SYSTEMS CO SUB OF CCI CORP
31-92B00222ESC CONTROL ELECTRONICS LLC DBA CONTROL ELECTRONICS DIVISION OF FIL-COIL
L680062-106845RAYTHEON COMPANY


Techincal Specification:
BODY WIDTH3.500 INCHES NOMINAL
INDIVIDUAL SECTION QUANTITY1
MATERIAL AND LOCATIONSTEEL CASE
INPUT IMPEDANCE RATING1.000 KILOHMS
MOUNTING FACILITYTHREADED HOLE
BODY STYLERECTANGULAR
THREAD SIZE AND SERIES/TYPE DESIGNATOR0.190-32 UNF
BODY LENGTH6.000 INCHES NOMINAL
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS3.000 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY16 WIRE HOOK
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS0.875 INCHES NOMINAL
SEGMENT DELAY TIME1.000 MICROSECONDS NOMINAL SINGLE SECTION 6TH SEGMENT
SEGMENT DELAY TIME1.600 MICROSECONDS NOMINAL SINGLE SECTION 7TH SEGMENT
SEGMENT DELAY TIME100.000 NANOSECONDS NOMINAL SINGLE SECTION 2ND SEGMENT
SEGMENT DELAY TIME200.000 NANOSECONDS NOMINAL SINGLE SECTION 3RD SEGMENT
SEGMENT DELAY TIME400.000 NANOSECONDS NOMINAL SINGLE SECTION 4TH SEGMENT
SEGMENT DELAY TIME50.000 NANOSECONDS NOMINAL SINGLE SECTION 1ST SEGMENT
SEGMENT DELAY TIME800.000 NANOSECONDS NOMINAL SINGLE SECTION 5TH SEGMENT
DELAY TIME VARIATION METHODTAPPED
MOUNTING PROVISION ARRANGEMENT STYLEFOUR POSITION RECTANGULAR
SEGMENT QUANTITY PER SECTION7 SINGLE SECTION
BODY DEPTH1.500 INCHES NOMINAL
SECTION DELAY TIME4.150 MICROSECONDS NOMINAL SINGLE SECTION
MOUNTING FACILITY QUANTITY4
SIGNAL DELAY METHODINDUCTANCE