5895-01-348-8640 MIXER STAGE,FREQUENCY Index 5955-01-348-8642 OSCILLATOR,CRYSTAL CONTROLLED

National Stock Number:
5955-01-348-8641

Federal Supply Class:
5955

National Item Identification Number:
013488641

Description:
OSCILLATOR,CRYSTAL CONTROLLED

Detail:
An oscillator whose operating frequency(ies) is controlled by a CRYSTAL UNIT, QUARTZ. For an oscillator controlled by a device other than a crystal, see OSCILLATOR (1), NONCRYSTAL CONTROLLED. See also GENERATOR, SIGNAL; and CALIBRATOR, FREQUENCY. Excludes FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; and OSCILLATOR, PULSE DELAY.


Manufacturer Information:
M55310/09-B11A24M0000081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-O-55310/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-55310/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
AVERAGE LIFE MEASUREMENTNOT RATED
BASIC SHAPE STYLECYLINDRICAL
CIRCUIT CONSTRUCTION TYPESOLID STATE
CONNECTION CONTACT TYPE AND QUANTITY8 PIN EXTERNAL
CONNECTION TYPE AND LOCATIONPIN BOTTOM
CONTROL TYPEREMOTE
EXTERNAL DC OPERATING VOLTAGE IN VOLTS5.0 NOMINAL SINGLE VOLTAGE
FREQUENCY PER CHANNEL24.0 MEGAHERTZ NOMINAL OPERATING CHANNEL
INCLOSURE TYPEHERMETICALLY SEALED
INSTALLATION DESIGNMODULE
OPERATING CONTROL METHODAUTOMATIC
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
OVERALL DIAMETER0.410 INCHES MAXIMUM
OVERALL LENGTH0.780 INCHES NOMINAL
SPECIFICATION/STANDARD DATA81349-MIL-O-55310/9 GOVERNMENT SPECIFICATION
STORAGE TEMP RANGE-62.0 TO 125.0 CELSIUS
TEST DATA DOCUMENT81349-MIL-O-55310 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial