DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 2.100 INCHES NOMINAL |
OVERALL LENGTH | 1.730 INCHES MAXIMUM |
OVERALL WIDTH | 1.310 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PRECIOUS MATERIAL | GOLD |
PRECIOUS MATERIAL AND LOCATION | TERMINALS GOLD |
PURPOSE FOR WHICH DESIGNED | GENERAL |
WINDING QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
TIME DELAY | 0.025 SECONDS MAXIMUM FIXED RELEASE TIME |
TIME DELAY | 30.00 SECONDS MAXIMUM FIXED OPERATE TIME |