DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.844 INCHES NOMINAL SECOND MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC AND 6.0 AMPERES DC INDUCTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 2.156 INCHES MAXIMUM |
OVERALL LENGTH | 2.187 INCHES MAXIMUM |
OVERALL WIDTH | 1.531 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL FIRST MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SECOND MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TRIANGLE SECOND MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.142 INCHES MINIMUM AND 0.152 INCHES MAXIMUM SECOND MOUNTING FACILITY |
WINDING QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |