DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
CRITICALITY CODE JUSTIFICATION | FEAT |
CUBIC MEASURE | 0.046 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT AND VIBRATION PROOF AND SHOCK PROOF |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 MILLIAMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 28.0 MILLIAMPERES DC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 0.375 INCHES MAXIMUM |
OVERALL LENGTH | 0.370 INCHES MAXIMUM |
OVERALL WIDTH | 0.335 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
SPECIAL FEATURES | FAILURE RATE LEVEL OF 0.100 PERCENT PER 10,000 CYCLES |
WINDING DC RESISTANCE RATING | 3.2 KILOHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 9 PIN ALL FUNCTIONS |
TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |
TIME DELAY | 0.0075 SECONDS MAXIMUM FIXED RELEASE TIME |