1440-00-992-9684 PISTON ASSEMBLY Index 5950-00-992-9686 TRANSFORMER,POWER

National Stock Number:
5945-00-992-9685

Federal Supply Class:
5945

National Item Identification Number:
009929685

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
154741410001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
231B244AFP3163743WARD LEONARD CT LLC
231B244AFPART3102989GENERAL ELECTRIC CO GE DRIVE SYSTEMS GOVERNMENT BUSINESS OPN
7022L8AN89020TYCO ELECTRONICS/AGASTAT RELAYS


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CASE MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT0.500 INCHES NOMINAL SECOND MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT0.750 INCHES MINIMUM AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.750 INCHES NOMINAL SECOND MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.880 INCHES NOMINAL FIRST MOUNTING FACILITY
COIL QUANTITY1
CUBIC MEASURE45.392 CUBIC INCHES
ENERGIZING ELEMENT POWER RATING8.0 WATTS
ENVIRONMENTAL PROTECTIONDUSTPROOF
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZ60.0 NOMINAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 15.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS240.0 AC AND 30.0 DC
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT4.520 INCHES MAXIMUM
OVERALL LENGTH3.250 INCHES MAXIMUM
OVERALL WIDTH3.090 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE SECOND MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE FIRST MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR SECOND MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR FIRST MOUNTING FACILITY
NOMINAL THREAD SIZE0.164 INCHES SECOND MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
PURPOSE FOR WHICH DESIGNEDGENERAL
WINDING QUANTITY1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY8 SCREW ALL FUNCTIONS
THREAD CLASS2B SECOND MOUNTING FACILITY
THREAD DIRECTIONRIGHT-HAND SECOND MOUNTING FACILITY
THREAD QUANTITY PER INCH32 SECOND MOUNTING FACILITY
THREAD SERIES DESIGNATORUNC SECOND MOUNTING FACILITY
TIME DELAY0.10 SECONDS MINIMUM AND 1.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME
UNTHREADED MOUNTING HOLE DIAMETER0.199 INCHES NOMINAL FIRST MOUNTING FACILITY