5930-01-347-5605 SWITCH,PRESSURE Index 5930-01-347-5607 SWITCH,PUSH

National Stock Number:
5930-01-347-5606

Federal Supply Class:
5930

National Item Identification Number:
013475606

Description:
SWITCH,PRESSURE

Detail:
A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.


Manufacturer Information:
1153P005998087ITT AEROSPACE CONTROLS LLC


Techincal Specification:
BODY DIAMETER0.880 INCHES NOMINAL
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
CONTACT LOAD CURRENT RATING10.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE AND 200.0 MILLIAMPERES LAMP LOAD SINGLE VOLTAGE
CONTACT STIMULUS RATING6.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH AND 5.50 DEACTUATION POINT MINIMUM POUNDS PER SQUARE INCH
CONTACT VOLTAGE RATING IN VOLTS28.0 DC AT SEA LEVEL SINGLE VOLTAGE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONVIBRATION RESISTANT
INSIDE DIAMETER0.5625 INCHES NOMINAL FIRST CONNECTION
III STYLE DESIGNATORCYLINDRICAL
PRESSURE CONNECTOR TYPEGASKET SEAL, THREADED INTERNAL FIRST CONNECTIONFLARELESS, THREADED EXTERNAL SECOND CONNECTION
PRESSURE SWITCH TYPEDIFFERENTIAL
PROPRIETARY CHARACTERISTICSPACS
PROOF PRESSURE12.00 POUNDS PER SQUARE INCH GAGE
MEDIA FOR WHICH DESIGNEDGAS
MOUNTING METHODINPUT PORT
NOMINAL THREAD SIZE0.5625 INCHES FIRST PRESSURE CONNECTION0.5625 INCHES SECOND PRESSURE CONNECTION
NONPILE-UP CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING TEMP RATING-65.0 DEG FAHRENHEIT MINIMUM AND 170.0 DEG FAHRENHEIT MAXIMUM
OUTSIDE DIAMETER0.5625 INCHES NOMINAL SECOND CONNECTION
OVERALL DIAMETER1.500 INCHES NOMINAL
OVERALL LENGTH3.665 INCHES NOMINAL
TERMINAL TYPECONNECTOR, RECEPTACLE
THREAD CLASS3B FIRST PRESSURE CONNECTION3A SECOND PRESSURE CONNECTION
THREAD SERIES DESIGNATORUNJF FIRST PRESSURE CONNECTIONUNJF SECOND PRESSURE CONNECTION